Find out more about cookies. Plates can be found on the front, back, side, rim or base of Baumatic appliances - as indicated below. Aftersales Service. Book a Repair. Local engineers Genuine replacement parts 12 months guarantee Transparent pricing policy. Advice Centre. Buy Spare Parts. Search for your appliance. Where can I find my product code? Your Expert Appliance Repair Service Hoover Candy Baumatic Group engineers use only genuine Baumatic parts and will come out to your home to repair your appliance at a time that suits you.
Why Choose Baumatic? Transparent and fair pricing policy With Baumatic there are no hidden extras, so you know exactly what you're paying for and how much it will be. A name you can trust Baumatic is a household name with a reputation for appliances that are fashionable and innovatively designed. Remove the six screws securing the control panel to the door. The control panel will drop down and be free of the door.
But, the wiring will still connected to the control panel. The minority of models locate the PCB on the side of strengthening muscle.
You can judge the location by the newest exploded view Midea sent you. Disconnect the connector form PCB. Remove the screws securing the PCB to control panel. Remove the PCB. Reverse the above procedure to install. But the marks on PCB have the same meaning described on the left side.
Valves are normally closed. Each time the appliance requires water, the controller will convey an electric signal to the coils to open the valves. The inlet valve consist of electric coil, valve body, valve pole, filter etc. In a word, the electromagnetic valve can act to allow water enter into machine, when it receive the order given by controller. The defeat point 1. It will cause the E1 error.
It will cause the E1 or E4 error. Disconnect power. Remove the water inlet hose. Note : Be careful of remain water drop. Remove the baseboard, left baseboard, left side panel and middle rear crosspiece. Left side panel 4. Middle rear crosspiece 4. Disconnect the 2 terminal lugs from the inlet valve. Push the valve from the lower rear crosspiece to take it off.
Remove the clamp and disconnect the inlet hose to air breaker from the water valve. Baseboard 2. Left baseboard Inlet valve Attention: Build in models have no Baseboard and left and right baseboard, but adjustable baseboard.
Inspect inlet valve Check electric part 1. Open the control panel and take out the PCB; 2. I f the measured resistance is not correct, it means the valve coil is broken or the connector is loose. In this case, we should check the connection first.
If the resistance is OK, we need to inspect the valve body. If the electric part is OK, we need to check the machine part. Remove the baseboard, left baseboard, top panel, left side panel and middle rear crosspiece. Check the valve filter. If the water is continue entering, we need replace the valve. Drain pump is a kind of pump driven by permanent magnet synchronous motor.
The rotor is made with permanent magnet material, the running inertia of rotor is very small, the stator consist of silicon steel stack and coil. When the drain pump is on power, the rotor will be very easy to start. It will cause the E2 , E4 or E1 error. The magnetism of motor rotor is weak, so drain pump cannot work. It will cause the E2, E4 or E1 error. The drain pump assembly rack is loose, it will cause noise. The non-return valve is bad, the remain water is too much. If not, wet the floor.
Remove four screws on bottom, and then remove bottom board. Label and disconnect the two terminal lugs from the drain pump. Remove screws securing the drain pump to sump, then remove drain pump. Inspect drain pump Check the electric part 1. If the measured resistance is not correct, it means the pump coil is broken or connector is loose. IS PS Check the machine part 1. Remove bottom board. If the non-return valve is wrongly assembled, the tub will remain much water.
We need to re-assemble the non-return valve. If the drain pump is working, but no water drain out or just a little. We should check the drain hose or drain body. The heater coil is broken, so the heater cannot work. It will cause the E3 error. The thermostat is active, so the heater cannot work. The connector is loose, so the heater cannot work. Drain off the water in the dishwasher, and disconnect the power supply.
Note : Make sure to remove remained water in the dishwasher. If not, wet the floor 2. Label and disconnect the terminals to and ground wire. Remove the 2 clamps from the Heating element. Replace the old clamp with a new universal clamp. Inspect heater 1. If the measured resistance is not correct, it means the heater coil or the thermostat is broken, we should replace the heating element or the thermostat.
The stator consist of silicon steel stack and two coils, main coil and assistant coil. It will cause E3 error. In this case, it will send out the electromagnetism noise. If it is continue electrifying motor, the thermal protector will work.
The drain pump assembly bracket is loose, it will cause noise. Label and disconnect the 2 terminals to the capacitor. Label and disconnect the 2 terminals to the motor wire connector. Remove the clamp fastening the interconnect hose to the sump. Replace the old clamp with a new universal clamp Dia Remove the clamp fastening interconnect hose to the lower nozzle.
Remove the clamp fastening interconnect hose to heater. Remove the screw and disconnect the ground wire from the wash pump motor assembly. Note: Do not attempt to remove the bolt and locknut connecting the motor mount to the dishwasher frame. Remove the motor pump assembly from the dishwasher.
Inspect Washing Pump Check the electric part 1. Open the control panel and take out PCB; 2. I f the resistance is not correct, it means the pump coil is broken or the connector is loose, In this case, we should check the connection first. If the resistance is OK but it cannot work, it maybe the capacitor weakly, we need to replace the capacitor.
IS ML Check the machine part 1. Check the pump assembly, if the bracket is loose, it will bring the noise, we need to tighten it. If the drain pump is working, but no water out or just a little.
We should check the vane wheel. The contact can be calibrated to trip and reset at the desired pressure levels, The main application is to control the level of water in appliances. May also provide flood protection. Access Washing Pump 1. Remove two screws securing the NTC to sump shown in above picture. Take out NTC. I f the resistance is not correct, it means NTC circuit has a problem. The work principle Flowmeter is integrated into Air Breaker.
Function of Flowmwter is measure how much water has entered in appliance. Remove the baseboard, left baseboard and left side panel. Remove the plastic nut inside tub, which secures the air breaker to tub. Because flowmeter is integrated into air breaker, replace air breaker if flowmeter has failure.
Disconnect the wire and remove clamp fastening hose to air breaker. Take out air breaker. Inspect Flowmeter 1. Unplug the CON27 wire shown in below picture , then use the multi-meter Diode shelf to test whether electrical pulse is sent out from two black wires while water is passing through flowmeter, or not.
In this case, it means something wrong with flowmeter circuit. We should check the connection first. The work principle Mechanical Aquastop Hose Electronic Aquastop Hose There are two types of Safety Hose, mechanical Aquastop hose and electronic Aquastop hose, which have different principles and assembly modes. Mechanical Aquastop safety hose has two layers. If water leak and fill the air space between two layers, the foaming material will expand and lock the hose.
In this situation, the machine might set off E1 alarm. Electronic Aquastop safety hose also has two layers. But the difference from mechanical is that if the water leak and flow on the bottom tray, the flooding pressure switch on the tray will act, the electromagnetic valve on the hose will cut off the water road and the machine will set off E4 alarm.
Remove baseboard, side baseboard, top panel and left side panel. Remove clamp, cut the bound belt and disconnect the wire connector. Then the Inlet hose cane pulled out. Reverse the above procedure to assemble. Mechanical Aquastop Hose Mechanical Aquastop hose is connected to appliance just as universal water inlet hose.
Open circuit and short circuit are both incorrect. Label and disconnect the 2 terminals. Remove the screws fastening the diverter valve to pump. The appliance will pause and stand by as step Then close the door and press Program button to start the Test Program. During test program running, you can press Program button to jump into next step except inlet valve step. Note: The way to activate test program is slightly different between different models.
Then the machine will pause. Open inlet valve and feeds with 3. Inlet valve and Regeneration Open regenaeration valve and feed with 0. Buzz one, then pause.
Baumatic Oven AS15 User and installation instructions manual 32 pages, 0. Baumatic Oven AS2 User and installation instructions manual 32 pages, 1. Baumatic Manuals. Baumatic Refrigerator Maintenance and user manual 12 pages. Baumatic BCI Manuals. Baumatic Refrigerator BF Instruction manual 25 pages, 0. Baumatic Refrigerator BF Instruction manual 21 pages, 0.